Ventilation is only effective if indoor air is fully expelled from the building. Just because a vent is visible or audible does not guarantee it’s working efficiently. One of the most common issues with buildings is improper ducting. Exit speeds are often overlooked by builders, regulators, surveyors, and end users.
Basic Check for Vent Ducting
When a vent passes through a standard brick wall and you can see both sides, the vent is likely ducted out of the building. But what if that’s not the case, or something is blocking the airflow?
How to Verify Air is Properly Exiting the Building 🕵️♂️💨
- Use an Anemometer 🌬️🔧
- Run one internal fan at a time.
- Use an anemometer (with a funnel for improved accuracy) to measure the airflow exiting the building.
- Ensure the exit speed matches the fan speed. If it does, the ventilation is likely effective.
Common Issues That May Cause a Drop in Vent Speed:
- 🔄 Shared Ducting:
- 🕳️ Leaking Ducting:
- A leak in the ducting can cause vapour to escape into voids such as ceilings or loft spaces, leading to condensation issues in those areas.
What if You Can’t Find the Vent Outlet? ❓🏠
- Check for Chimney Venting 🏡🪵
- Venting through chimneys can be challenging:
- Verification Difficulty: It’s hard to check if air is exiting and at what speed.
- Performance Drop: Long distances can reduce vent efficiency.
- Backdraft Risk: Vapour blown up the chimney may return, causing internal damp problems.
- Venting through chimneys can be challenging:
- Alternative Methods to Locate the Vent Outlet 🔍💨
- Steam Test: On a cold day, steam up the bathroom, turn on the fan, and look for vapour exiting the building.
- Smoke Test:
- Use a smoke pellet (follow manufacturer’s instructions). Be cautious of smoke spreading and notify other occupants.
- Alternatively, use smoke from a cigar or similar (with care to avoid fire hazards or smoke spreading).
Next Steps 🛠️
For solutions to vent issues, see [Fix Vent] 🛠️💨 for common fixes and improvements.