Hygroscopic salts are a common cause of persistent damp patches in buildings. They can often be misdiagnosed as rising damp or condensation. The following video provides a clear example of hygroscopic salts appearing on a chimney breast, demonstrating how these salts cause damp-like symptoms without active water ingress:

Example of Hygroscopic Salts on a Chimney Breast:

Hygroscopic Salts

Definition:
Hygroscopic salts are salts that absorb moisture from the atmosphere. Common types found in buildings include calcium nitrate and calcium sulphate. They are primarily introduced from historic sources like coal-burning residues, animal excretions (e.g., from horses), de-icing salts, and occasionally rising damp.

Characteristics:

  • Appear as damp patches even in dry weather.
  • Commonly misdiagnosed as rising damp or condensation.
  • Present as horizontal bands up to approximately 1 metre from the ground or as vertical streaks on chimney breasts.
  • Do not cause structural damage but can lead to decorative spoiling.

Sources of Hygroscopic Salts:

  • Historic Coal Burning: Residues from coal combustion can leave salt deposits in walls, particularly in Victorian buildings.
  • Animal Presence: Stables, barns, or areas where horses and livestock were kept often have salt contamination.
  • De-Icing Salts: In regions where salt was used to prevent ice, residues can seep into masonry.
  • Rising Damp: Occasionally, salts from groundwater can rise into walls, though this is less common compared to other sources.

Methods for Identifying Hygroscopic Salts

  1. Visual Signs:
    • Horizontal Bands: Up to 1 metre above ground level.
    • Vertical Streaks: On chimney breasts.
  2. Lack of Heat Signature on a Thermal Lens:
    • Thermal Imaging: Damp patches caused by hygroscopic salts do not exhibit a clear heat signature when viewed through a thermal lens, as no active moisture ingress is present.
  3. Laboratory Analysis:
  4. Relative Humidity Testing with a Data Logger:
    • Procedure:
      • Take a sample of the affected plaster or masonry.
      • Place it in a small sealed vessel with a data logger to measure humidity.
      • Gradually increase and decrease the relative humidity.
    • Identification:
      • If the relative humidity stabilises (buffers) around 50% RH, the sample likely contains calcium nitrate, which deliquesces at this level.
  5. Damp Meter Readings:
    • Elevated moisture readings during periods of high humidity, even in summertime.
  6. Absence of Mould:

Deliquescence

Definition:
Deliquescence is the process by which certain salts absorb moisture from the atmosphere until they dissolve and form a liquid solution. Unlike typical condensation, deliquescence occurs at relative humidity levels below 100% RH.

Key Points:

Calcium nitrate deliquesces at a relative humidity of 50% RH at 20°C.

Relation to Internal Dampness

Hygroscopic salts in masonry can attract vapour, creating the appearance of persistent dampness. This can occur year-round, including summer.

Common Indicators:

  • Damp Patches: Even in dry weather or during periods of high humidity.
  • Absence of Mould: Areas affected by hygroscopic salts may inhibit mould growth due to reduced relative humidity on the wall surface.
  • Fireplaces and Chimney Breasts: Horizontal or Vertical damp bands are common in older homes with fireplaces that have been altered, such as replastering, or otherwise become damp.

Relationship with Mould Growth

Methods for Identifying Deliquescence

  1. Visual Signs: Unexplained damp areas without visible water ingress.
  2. Laboratory Analysis: Testing plaster or masonry samples for hygroscopic salts.
  3. Damp Meter Readings: Elevated moisture readings during high-humidity periods (including summer).
  4. Absence of Mould: Damp patches without mould growth.
  5. Absence of heat loss when using a thermal lens: hygroscopic salts are in dynamic equilibrium, therefore there is no heat loss from evaporation.

Remedial Actions

  1. Cover with Oil-Based Primer:
    • Apply two coats of an oil-based primer like Zinsser Cover Stain.
    • Best applied when the wall is dry, achievable by using a dehumidifier set below 50% RH and a fan.
  2. Install Impermeable Insulation:
    • Use materials like PIR boards (e.g., Celotex) bonded with plasterboard.
    • These prevent moisture effects while improving thermal insulation.
  3. Remove Contaminated Material:
    • Strip back plaster to at least 300 mm beyond the affected area.
    • Typically unnecessary, disruptive, and expensive.
  4. Replaster with Salt-Resistant Plaster:
    • Consider renovating plaster that resists salt penetration.
    • Usually not required unless severe contamination persists.
  5. Apply a Salt Inhibitor:
    • Treat walls with a salt-neutralising solution before replastering.
    • Generally unnecessary unless part of a larger treatment plan.
  6. Pumice in Plaster:
    • Historically used to draw out salts but less effective compared to modern methods.
    • Not a recommended contemporary solution.

Conclusion